{"created":"2023-06-19T09:37:41.019111+00:00","id":1506,"links":{},"metadata":{"_buckets":{"deposit":"f9ce6f1f-dca2-4809-8b32-59fc9541efaf"},"_deposit":{"created_by":2,"id":"1506","owners":[2],"pid":{"revision_id":0,"type":"depid","value":"1506"},"status":"published"},"_oai":{"id":"oai:ngu.repo.nii.ac.jp:00001506","sets":["1:24:328"]},"author_link":["2529","2528"],"item_10002_alternative_title_1":{"attribute_name":"その他(別言語等)のタイトル","attribute_value_mlt":[{"subitem_alternative_title":"3ジクカソクドセンサーナイゾウカツドウリョウケイノヒカク"}]},"item_10002_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2023-03-31","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"2","bibliographicPageEnd":"12","bibliographicPageStart":"1","bibliographicVolumeNumber":"11","bibliographic_titles":[{"bibliographic_title":"名古屋学院大学論集 医学・健康科学・スポーツ科学篇"},{"bibliographic_title":"THE NAGOYA GAKUIN DAIGAKU RONSHU; Journal of Nagoya Gakuin University; MEDICAL, HEALTH, and SPORTS SCIENCES","bibliographic_titleLang":"en"}]}]},"item_10002_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":" 本研究では,ActiGraph社製活動量計wGT3X-BTとオムロンヘルスケア社製活動量計HJA-750Cで評価される歩数や活動強度別時間の一致度を明らかにすることを目的とした。対象者は73名(女性56.2%,年齢73.2±5.4歳,身長157.5±8.4cm,体重56.2±9.3kg,BMI22.6±2.1)であった。対象者に,wGT3X-BTとHJA-750Cを1週間,起床から就寝まで装着させ,歩数,低強度活動時間,中高強度活動時間を測定した。分析には,対象者がいずれかの機器を600分以上装着した486日のデータを用いた。歩数は両機器で類似した値であったが,低強度活動時間はwGT3X-BTがHJA-750Cに比べて大きく,中高強度活動時間はHJA-750CがwGT3X-BTに比べて大きかった。両活動時間を専用のソフトを用いて変換すると,wGT3X-BTとHJA-750Cの測定値の差は小さくなった。HJA-750Cは,wGT3X-BTに比べ歩数は同等であったが,低強度活動時間が過小評価,中高強度活動時間が過大評価されることが明らかになった。HJA-750Cによって計測されたデータを専用ソフトで変換することにより機器間の一致度が高まる可能が明らかになった。","subitem_description_type":"Abstract"}]},"item_10002_identifier_registration":{"attribute_name":"ID登録","attribute_value_mlt":[{"subitem_identifier_reg_text":"10.15012/00001453","subitem_identifier_reg_type":"JaLC"}]},"item_10002_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"名古屋学院大学総合研究所"}]},"item_10002_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"2187-5162","subitem_source_identifier_type":"ISSN"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"坂井, 智明"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2023-03-31"}],"displaytype":"detail","filename":"igakukenkou_vol1102_01.pdf","filesize":[{"value":"2.7 MB"}],"format":"application/pdf","license_note":"Copyright (c) 2023 坂井智明","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"igakukenkou_vol1102_01.pdf","url":"https://ngu.repo.nii.ac.jp/record/1506/files/igakukenkou_vol1102_01.pdf"},"version_id":"50a961f7-5c6b-4e45-ba1a-afea954b14a9"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"高齢者 ","subitem_subject_scheme":"Other"},{"subitem_subject":" 身体活動量 ","subitem_subject_scheme":"Other"},{"subitem_subject":" HJA-750C ","subitem_subject_scheme":"Other"},{"subitem_subject":" wGT3X-BT ","subitem_subject_scheme":"Other"},{"subitem_subject":" Bland-Altman plot","subitem_subject_scheme":"Other"},{"subitem_subject":"elderly ","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":" physical activity ","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":" HJA-750C ","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":" wGT3X-BT ","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":" Bland-Altman plot","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"3軸加速度センサー内蔵活動量計の比較","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"3軸加速度センサー内蔵活動量計の比較"},{"subitem_title":"Comparison of tri-axial accelerometers, Active Style Pro with ActiGraph","subitem_title_language":"en"}]},"item_type_id":"10002","owner":"2","path":["328"],"pubdate":{"attribute_name":"公開日","attribute_value":"2023-03-31"},"publish_date":"2023-03-31","publish_status":"0","recid":"1506","relation_version_is_last":true,"title":["3軸加速度センサー内蔵活動量計の比較"],"weko_creator_id":"2","weko_shared_id":-1},"updated":"2023-06-19T09:44:57.275640+00:00"}